• Ask The Experts Blog
  • GROUNDING SERVICES
    • Overview
    • Grounding System Evaluations & Audits
    • Grounding Design & Lightning Strike Analysis
    • Power Quality Monitoring and Load Analysis
    • Soil Resistivity Testing
    • Ground Potential Rise Studies (GPR)
    • Cell Site Grounding Requirements
  • ABOUT ELECTRICAL GROUNDING
    • Overview
    • Sphere Of Influence
    • Different Types of Grounding Electrodes
    • Electrical Grounding System Design
    • Soil Resistivity Testing
    • Electrical Grounding System Testing
    • Ground Potential Rise
    • Step and Touch Potential
    • Standards For Lightning Protection Systems
  • GROUNDING TRAINING
  • ARTICLES & RESOURCES
    • What is Lightning?
    • Grounding Frequently Asked Questions
    • Electrical Grounding Articles & Resources
  • ABOUT US
ESGroundingSolutions
Join Us On Facebook Join Us On LinkedIn

Grounding Services

 
Call today for a free consultation
on your electrical grounding project
TOLL FREE: (888) 367-0888

Cell Site Grounding And Telecommunications Grounding Requirements

The experts at E&S Grounding Solutions provide comprehensive cell site and telecommunications grounding solutions

Proper electrical grounding is essential for Cell Sites, BTS Cellular Base Stations, telecommunications or wireless network equipment deployement. Our cell site grounding and telecommunications grounding methods closely follow the Motorola R56 standards and IEEE Std 142-1991 and IEEE Std 142-2007 recommended Practice for Grounding of Industrial and Commercial Power Systems guidelines for cell site and telecommunications sites.

We meet the 5 Ohm resistance to ground requirement to keep your valuable cell site and telecommunications equipment within warranty

Nowdays many equipment vendors and telecommunications companies require ground systems at 5 Ohms resistance to ground. According to the IEEE Std 142-1991 and IEE Std 142-2007 (The Green Book), the grounding electrode resistance of large electrical substations should be 1 Ohm or less. For commercial and industrial substations including cell site and telecommunications sites the recommended resistance to ground is 5 Ohms or less. This low resistance is required due to the high potential to earth of the electrical system. Depending upon the site location and soil characteristics, achieving that 5 ohm resistance can be very difficult. With proper soil resistivity testing however, we can provide communication tower grounding solutions that will achive 5 ohm resistance to ground and meet the stringent requirements such as the Motorola R56 standard to keep your valuable equipment within warranty.

The experts at E&S Grounding Solutions provide comprehensive cell site and telecommunication tower grounding solutions for Cell Site electrical grounding or BTS Cellular Base Station electrical grounding. Our cell site grounding and telecommunication tower grounding services protect your valuable equipment!

  • Single point ground design
  • Location Wenner 4 point soil resistivity testing
  • Maintaining grounding requirements at the NEC (Network Interface Device)
  • Grounding hardware such as generators, power plant, battery pack and air conditioning units
  • Ground rod placement
  • Grounding OSP (Out Side Plant) cables
  • Complying with electrical safety requirements
cell tower picture

BTS sites (Base Transmitter Station), cell sites, cellular towers and telecommunications centers must provide highly reliable phone and data communications, and in order to maintain this level of service the equipment and grounding must meet NEBS requirements (Networks Element Building Standards). Our electrical grounding solutions compliant with IEEE Std 142-1991 and IEE Std 142-2007 ensure that your high performance equipment is protected.

We provide safe and compliant cell site grounding design

Our BTS cellular base station cell site grounding and telecommunications grounding design solutions are based on NEBS compliance and the following telecommunication networks compliance standards:

  • TR-NWT-000295
  • GR-1275
  • NEC 2008
  • IEEE Std 142-1991 and IEE Std 142-2007
Share/Bookmark
Win A Tablet PC. All you have to do to Win A Tablet PC is click here. Once you click, you will be entered to Win A Tablet PC. CLICK HERE Grounding Electrodes Explained Download our free White Paper which covers the features and benefits of many different grounding electrodes, the importance of soil resistivity and much more. CLICK HERE Ask the Experts Submit a question regarding electrical grounding. CLICK HERE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  • Overview
  • Grounding System Evaluations, Audits and Regulatory Compliance
  • Grounding System Design and Lightning Strike Analysis
  • Power Quality Monitoring and Load Analysis
  • Soil Resistivity Testing
  • Ground Potential Rise Studies (GPR)
  • Cell Site Grounding Requirements
  • HOME
  • GROUNDING SERVICES
  • ABOUT ELECTRICAL GROUNDING
  • ARTICLES AND RESOURCES
  • COMPANY
  • PRIVACY & DISCLAIMER

© 2013 E&S Grounding Solutions. All rights reserved.